Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Two hundred fifty milliliters of each product wereused at full strength in a 4000 ml beaker and heated to its boiling point on a hot plate. Preweighed aluminum coupons were coated with the Cargill, Inc Canola Oil (120962-03-0) using a handheld swab. Coupons were weighed a second time to determine the amount of soil added to each coupon. Three coupons were cleaned in each solution for 5 minutes using vapor degreasing. After cooling to room temperature, the coupons were weighed a final time and efficiencies were calculated.