Default object view. Click to create a custom template, Node ID: 6760, Object ID: 6759

Trial #445

Trial #445

removing preinco #47 lube of the surface of aluminum using non-toxic cleaners.

2008

0

1

930

930

Coupon

05/20/2008

5.00

Immersion/Soak

There are no related objects.

Aluminum

Tap water rinse

Air Blowoff

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Products were based on the compatibility of substrate and removal of foreign substance. Used 5% concentration and heated the samples at 135F. The coupons were immersed in a product for 5 minutes, rinsed for 30 seconds in tap water at 120F and dried in 30 seconds.

Cleaner Initial wt Final wt % Removed
Nab 9000      
  0.4618 0.0618 86.62
  0.4430 0.0406 90.84
  0.4999 0.0343 93.14
ozzy juice sw1      
  0.5511 0.0294 94.67
  0.3082 0.0352 88.58
  0.3728 0.0329 91.17
valtron sp2275      
  0.3376 0.0066 98.05
  0.4096 0.0080 98.05
  0.4900 0.0169 96.55
sea wash blue      
  0.6640 0.0084 98.73
  0.7212 0.0062 99.14
  0.5934 0.0049 99.17
ozzy juice sw3      
  0.3304 0.0025 99.24
  0.4652 0.0025 99.46
  0.4105 -0.0006 100.15
california parts washer      
  0.7186 0.0409 94.31
  0.4873 0.0223 95.42
  0.4227 0.0208 95.08

All products tested surpassed the approval removal rate of 85%.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Document Evaluation #2 Evaluation 3
Document Evaluation #3 Evaluation 3
Document Evaluation #4 Evaluation 3
Document Evaluation #5 Evaluation 3
Powered by eZ Publish™ CMS Open Source Web Content Management. Copyright © 1999-2014 eZ Systems AS (except where otherwise noted). All rights reserved.