Default object view. Click to create a custom template, Node ID: 6773, Object ID: 6772

Trial #458

Trial #458

To test nontoxic industrial cleaning solution for oil removal.

2008

0

1

942

942

Coupon

11/03/2008

5.00

Immersion/Soak

There are no related objects.

Stainless Steel

Oil

Tap water rinse

Air Blowoff

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Products were selected based in the compatibility of substrate and removal of foreign substance. Used 10% of concentration and heated the samples at 135 F. The coupons were immersed in a product for 5 minutes, dried in 30 seconds using compressed air is room temperature. The contaminated coupons were weighed again to determine the amount of soil added. After cleaning process, the final weights were recorded, efficiencies were calculated and recorded.

Cleaner Initial wt Final wt % Removed
Kyzen Corporation Optisol Op7432      
  0.5136 0.4399 14.36
  0.3518 0.1498 57.42
  0.2410 0.0542 77.51
Kyzen Corporation Optisol Op7168      
  0.5370 0.2175 59.50
  0.3416 -0.0283 108.28
  0.3664 -0.0275 107.51
Brulin Corporation,Metalnox      
  0.1288 0.0088 93.17
  0.1883 0.0096 94.90
  0.1045 0.0059 94.35

The Optisol Op7432 cleaned better than the others.