Default object view. Click to create a custom template, Node ID: 6786, Object ID: 6785

Trial #471

Trial #471

To test nontoxic industrial cleaning solutions for oil removal

2009

0

1

1004

1004

Coupon

02/09/2009

5.00

Immersion/Soak

There are no related objects.

Stainless Steel

Inks

Agitated tap water

Air Blowoff

Visual

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Products were selected based on the compatibility of substrate and removal of foreign substance. Used 5% concentration and heated the samples at 135F. The steel coupons were immersed in a product for 5 minutes, rinsed for 30 seconds in tap water at 120F and dried in 30 seconds using compressed air is room temperature. Coupons were coated with used oil. Using a handheld swab and allowed to dry for 144 minutes at room temperature. The contaminated coupons were weighed again to determine the amount of soil added. After cleaning process, the final weights were recorded, efficiencies were calculated and recorded.

Kyzen Chemical, Industrial Floor Initial Wt Final wt % Removal
  0.0291 0.0026 91.07
  0.0098 0.0045 54.08
  0.0166 0.0015 90.96
Vertec Biosolvent      
  0.0432 0.0239 44.68
  0.0357 0.0138 61.34
  0.0200 0.0045 77.50
Seventh Generation      
  0.0234 0.0145 38.03
  0.5597 0.0569 89.83
  0.0185 0.0061 67.03
Sky Product Cleaner      
  0.0127 0.0064 49.61
  0.0378 0.0197 47.88
  0.0139 0.0092 33.81

No product removed over 85% of the graffiti from stainless steel using immersion cleaning.