Default object view. Click to create a custom template, Node ID: 27053, Object ID: 47320

Trial #1

Trial #1

Control testing to monitor bathroom soil consistency.

2021

29

2

100

100

Coupon

12/14/2021

0.00

Manual Wipe

There are no related objects.

Ceramics
Chrome
Plastic

None

Air dry

Gravimetric

Nine pre-weighed coupons, three of each substrate per cleaner, were each contaminated with ~0.5 gram of bathroom soil (28.6% All-in-one shampoo and conditioner, 21.4% Dry skin lotion, 21.4% Liquid Hand Soap, 14.3% Liquid body wash, 7.2% Deodorant bar soap, 7.1% Water). The dirty weights were recorded after the coupons had dried for 24 hours at room temperature (68 F). Three coupons of the same substrate were aligned into a Single Line Washing Unit (SLW) with The Wypall X60 attached to the cleaning sled. The Wypall X60 reinforced wipe along with the coupons were all sprayed two times with the cleaner and then allowed to soak for 30 seconds. Afterwards the Single Line Washing Unit (SLW) was activated and cleaned for 20 cycles. The clean coupons were all then allowed to dry overnight at room temperature before the final weights were recorded.

Cleaner Substrate Initial wt of cont. Final wt of cont. %Cont Removed % AVG % Overall
Water Chrome 0.5220 0.0840 83.91 84.97 85.83
0.8444 0.1341 84.12
0.4601 0.0604 86.87
Ceramic  0.5715 0.0834 85.41 85.85
0.5232 0.0776 85.17
0.5299 0.0690 86.98
Plastic 0.6144 0.0802 86.95 86.67
0.5535 0.0590 89.34
0.5220 0.0850 83.72

The overall removal percentage for this control test was 85.83%.

No relation