Default object view. Click to create a custom template, Node ID: 7018, Object ID: 7017

Trial #2

Trial #2

To identify additional products for the coating removal

2003

11

4

C

20

20

Coupon

09/01/2003

30.00

Ultrasonics

Jason Marshall

Plastic

Coatings

DI water rinse

Air Blowoff

Visual

One product that was partially successful in the previous trial was diluted to 20% using DI water in a 600 ml beaker. Four semi-aqueous products were used at full strength in 600 ml beakers. Three acidic aqueous products were also selected for evaluation. Two were used at full strength and the third was used diluted to 3 percent using DI water in a 600 ml beaker. All eight products were heated to 120 F using a Crest 40 kHz ultrasonic tank filled with water and degassed for 5 minutes. One lens was placed in each solution and cleaned for 30 minutes. Observations were made at 5, 10, 15, 20 and 30 minutes. Parts were rinsed in DI water for 15 seconds at room temperature and dried using air blow off also at room temperature.

Westech was the only product to remove the coating from the front of the lens. Kyzen Ionx FCR, Inland Tech EP 921 and Dynamold Solvents DS 104 all effected the coating on the back. The table below lists the observations made during the cleaning process.

Cleaner 5 min 10 min 15 min 20 min 30 min
Multi-Kleen no sign of cleaning same same same not tested
Ionox FCR became hazy some peeling; became cloudy when rinsed cloudy some flaking same
EP 921 became hazy some peeling; became cloudy some could be rubbed off when rinsed air blew off some of the flakes same
SC Supersolve no sign of cleaning same same same not tested
DS 104 became hazy flakey with air blowing off some cloudy peeling off same
Westech 4712 tiny spots on front same starting to remove coating  same majority of coating on front was removed with air blow off
Citranox no sign of cleaning same same same same
Geo Guard 3015  no sign of cleaning same few spots developing   same no change

Chem Tech Westech CT-4712 removed nearly all of the coating from the front side of the lens.  All eight lenses are being returned to client for inspection at their facility.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Document Evaluation #2 Evaluation 3
Document Evaluation #3 Evaluation 3
Document Evaluation #4 Evaluation 3
Document Evaluation #5 Evaluation 3
Document Evaluation #6 Evaluation 3
Document Evaluation #7 Evaluation 3
Powered by eZ Publish™ CMS Open Source Web Content Management. Copyright © 1999-2014 eZ Systems AS (except where otherwise noted). All rights reserved.