Trial #0

Trial #0

To verify cleanliness of three group samples provided by Umicore in a blind test.

2018

26

2

0

0

Part

12/13/2018

3.00

Manual Wipe

Aditi Patel
Sabrina Apel

Stainless Steel

None

Air dry

A 72 dynes/cm solution was used during this verification test based off of testing done by Kyzen. A corner of a clean swab was used to apply three lines of the dyne test solution on the surface of a button part. Visual observations were documented using a lighted magnifying glass. Lines that held their shape for three seconds was considered effective.

Parts Evaluated:(1) Sample A, (2) Sample B, (3) Sample C

Due to this being the third test for cleanliness verification and the risk of cross contamination, the dyne test solution does not reflect the results seen from the contact angle and white glove test. This test was conducted a month after the parts were received due to an internal delay. The contact angle and the white glove test would be considered to have a true reflection of the cleanliness for the button parts.

Part Number A B C
1 Yes Yes No
2 Yes No No
3 Yes Yes No
4 Yes No Yes
5 No Yes Yes
6 Yes No Yes
7 No Yes Yes
8 No No No
9 Yes Yes No
10 Yes Yes No

Table Key

Yes – Held dyne test solution line for 3 seconds

No – Did not hold dyne test solution line for 3 seconds

Sample A and B had over 50% of the sample with effective cleaning results. Sample C would not be considered effective with a 40% effective cleaning sample.