Default object view. Click to create a custom template, Node ID: 6795, Object ID: 6794

Trial #2

Trial #2

To evaluate successful cleaners under client conditions

2002

10

4

12

12

Coupon

08/06/2002

5.00

Ultrasonics

Jason Marshall

Copper

DI water rinse

Heat Gun

Gravimetric

Two products that were successful in the previous trial without wiping were selected for continued evaluation. The two solution was diluted to 1% using DI water in 600 ml beakers, heated to 130 F and degassed for 10 minutes in a Crest 40 kHz ultrasonic tank. In addition to the two successful cleaners, two other products were selected for further evolution. These products were used at the original 5% dilution and were heated as well as degassed as the first two products. Twelve preweighed coupons were coated with Jackson Lea Learok 7-S-3 Buffing compound (102-71-6, 14808-60-7, 1317-95-9). The buffing compound was applied by first heating it with a hot air gun and rubbing the coupons with the melted contaminant. Coupons were allowed to cool to room temperature and then weighed again. Three coupons were cleaned in the 1% solution for 1 minute using ultrasonic energy at 40 kHz and the 5% solutions cleaning lasted for 5 minutes. Following the cleaning, coupons were rinsed with a DI water bath for 30 seconds at room temperature and dried using a Master Appliance Heat Gun at 300 F for 15 seconds. Coupons were again allowed to cool to room temperature and then weighed a final time. Cleaning efficiencies were calculated and recorded.

The products used at 1% removed only a small amount (<30%) of the buffing compound from the coupons after 1 minute. Therefore, an additional 4 minutes was added to the cleaning time with vastly improved results. The products removed over 99% of the contaminant. Results for the 1% cleaning are listed in Table 1.

Table 1. 1% Cleaning Results

Cleaner Coupon 1 Coupon 2 Coupon 3 Average Std Dev 1 minute
Permag S-4 100.07 98.55 99.96 99.53 0.85 27.79
Micro 90 100.00 100.06 100.00 100.02 0.04 11.30

The 5% solutions also did not remove a majority of the buffing compound after the initial 10 minutes of cleaning. An additional cleaning time of 5 minutes (total of 15) was added. Results were comparable to the 1%, 5 minute cleaning requiring no wiping. Both products removed over 95%

Table 2. 5% Cleaning Results

Inproclean 3800 100.18 100.10 100.07 100.12 0.06
Daraclean 282 GF 98.92 94.07 98.63 97.21 2.72

The next phase of testing will be to clean actual parts when supplied by client.