Trial #1
Te evaluate successful cleaners from previous trial using ultrasonic energy
Three products from the previous trial were diluted to 5% and one was diluted to 3% (Citranox) in 600 ml beakers using DI water. Products were heated to 130 F in a Crest 40 kHz ultrasonic tank and degassed for 5 minutes.
Twelve preweighed coupons were coated with Milacron Marketing Company CIMTECH® 310 metal working fluid concentrate (102-71-6, 78-96-6, 26896-20-8) using a hand held swab. Coupons were then reweighed using a Denver Instruments A250 balance to determine the amount of contaminant added. Three coupons were immersed into each solution and cleaned for 5 minutes using ultrasonics. Coupons were rinsed for 15 seconds in a tap water bath at 120 F and finally dried using a Master Appliance Hot Air gun at 500 F for 30 seconds. After the coupons were dried, final weights were recorded and efficiencies calculated for each cleaning solution.
Three of the products removed over 99.5% of the machining fluid after the 5 minute ultrasonic cleaning. The fourth cleaner removed over 98%. The table below lists the amount of contaminant applied, the amount remaining and the efficiency for each coupon cleaned.
Table 1. Cleaning Efficiencies
| Cleaner
|
Initial wt
|
Final wt
|
% Removed
|
| Citrinox
|
0.4035
|
0.0000
|
100.00
|
|
|
0.4448
|
0.0002
|
99.96
|
|
|
0.3102
|
-0.0001
|
100.03
|
| EXP 1400
|
0.1648
|
0.0030
|
98.18
|
|
|
0.3373
|
0.0066
|
98.04
|
|
|
0.3734
|
0.0034
|
99.09
|
| SC A&M
|
0.2300
|
0.0001
|
99.96
|
|
|
0.3866
|
-0.0002
|
100.05
|
|
|
0.4697
|
-0.0002
|
100.04
|
| Daraclean
|
0.1286
|
0.0013
|
98.99
|
|
|
0.4267
|
-0.0001
|
100.02
|
|
|
0.2787
|
0.0005
|
99.82
|
The three successful products will be used in the next phase of testing on supplied parts.