Default object view. Click to create a custom template, Node ID: 6812, Object ID: 6811

Trial #2

Trial #2

To evaluate successful cleaners on supplied parts

2002

10

4

41

41

Part

10/09/2002

5.00

Ultrasonics

Jason Marshall

Stainless Steel

Tap water rinse

Air Blowoff
Air Knives

Visual
Wipe

Three products from the previous trial were selected for cleaning supplied parts. Two were diluted to 5% and one was diluted to 3% using DI water in 1500 ml beakers. All three products were heated to 130 F on a hot plate. Each solution was degassed for 5 minutes in a Crest 40 kHz ultrasonic tank. Several supplied parts were cleaned in each solution for 5 minutes using ultrasonic energy. Parts were rinsed in tap water at 120 F for 15 seconds, dried using air blow off at room temperature for 15 seconds, followed by a Master Appliance Heat Gun at 500 F for 30 seconds. Once dry parts were visible inspected and wiped with a white towel to determine cleanliness.

Contaminant: Milacron Marketing Company CIMTECH® 310 metal working fluid concentrate (102-71-6, 78-96-6, 26896-20-8)

Both Citranox and Daraclean 282 appeared to remove the fine layer of black contamination present on the dirty parts.  Upon wiping the surface with a kimwipe soaked with acetone resulted in no visible black on the parts cleaned in Citranox and very little for the Daraclean cleaned products.  The wipe test of the Aircraft & Metal Cleaner cleaned parts resulted in the appearance of the black residue.

Citranox worked the best out of the three cleaners, followed closely by Daraclean 282.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Document Evaluation #2 Evaluation 3