Default object view. Click to create a custom template, Node ID: 6425, Object ID: 6424

Trial #15

Trial #15

To evaluate selected cleaner on parts contaminated with buffing compound.

2008

16

3

12

12

Part

07/15/2008

5.00

Ultrasonics

Jason Marshall

Steel

None

None

Visual

Five products were diluted to 3% using DI water in a 1510 Branson 40 kHz ultrasonic tank and heated to 130 F. The products were degassed for five minutes.

A set of three soiled steel parts coated with buffing compound were immersed into the ultrasonic tank and cleaned for 5 minutes. Following cleaning, coupons were observed for cleanliness without a rinsing.

A second set of parts were cleaned at 160 F.

All parts cleaned were equally cleaned after five minutes of cleaning at both temperatures. Some water spots were visible on all parts, but no buffing compound residue remained.

Any of the five products could be used successfully to remove the buffing compound from the steel parts using ultrasonic cleaning.