Default object view. Click to create a custom template, Node ID: 6385, Object ID: 6384

Trial #3

Trial #3

To evaluate top products on the third supplied cutting fluid using ultrasonic cleaning.

2008

15

4

139

139

Coupon

06/18/2008

5.00

Ultrasonics

Jason Marshall

Steel

Tap water rinse

Air Blowoff

Gravimetric

The top six products were selected from the previous lab trial. Each product was diluted to 5% using DI water in 600 ml glass beakers. Solutions were heated to 130 F on immersed in a heat bath in a Branson 40 kHz ultrasonic tank. Products were degassed for five minutes.

Eighteen preweighed steel coupons were coated with the ChemSearch Aerolex Plus moly dry film lubricant by spraying the contaminant onto the surface. Coupons were weighed a second time to determine the amount of soil added. Three coupons were immersed into each product and cleaned for 5 minutes using ultrasonic agitation. Following cleaning, coupons were rinsed for 15 seconds in tap water at 120 F and dried using air blow off for 30 seconds at room temperature. Final weights were recorded, and efficiencies were calculated.

The aqueous products had difficulty removing the lubricant. One product had moderate success removing over 40% of the contaminant as determined by gravimetric analysis. The others had negative calculated removal even though the coupons showed visual signs of being cleaner. Visual estimates were made for lubricant removal in addition to the traditional gravimetric values.

The table lists the amount of soil added, the amount remaining after cleaning, the efficiency for each coupon cleaned and the visually estimated level of removal.

Cleaner Initial wt Final wt % Removed Visual Estimate Average Estimate
M Aero 0.0637 0.0843 -32.34 30  
  0.0345 0.0382 -10.72 40  
  0.0313 0.0593 -89.46 30 33.33
Polyspray Jet 790 xs 0.0325 0.0504 -55.08 35  
  0.0435 0.0696 -60.00 50  
  0.0421 0.0533 -26.60 50 45.00
Metalnox M6310 0.0352 0.0298 15.34 30  
  0.0451 0.0409 9.31 50  
  0.0405 0.0475 -17.28 50 43.33
Daraclean 282 GF 0.0376 0.0347 7.71 50  
  0.0371 0.0344 7.28 50  
  0.0442 0.0453 -2.49 45 48.33
Micro 90 0.0696 0.0510 26.72 50  
  0.0468 0.0187 60.04 65  
  0.0413 0.0208 49.64 60 58.33
Luminox  0.0447 0.0946 -111.63 20  
  0.0328 0.0569 -73.48 40  
  0.0412 0.0627 -52.18 40 33.33

A follow up test will be conducted on this soil with additional products. The  six products from this trial will still be used on the fourth soil.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Document Evaluation #2 Evaluation 3
Document Evaluation #3 Evaluation 3
Document Evaluation #4 Evaluation 3
Document Evaluation #5 Evaluation 3
Powered by eZ Publish™ CMS Open Source Web Content Management. Copyright © 1999-2014 eZ Systems AS (except where otherwise noted). All rights reserved.