Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate selected products on third supplied paint using ultrasonic cleaning.
Date Run:
05/11/2006Experiment Procedure:
Two products from the previous contaminant were diluted to 5% using DI water in 600 ml beakers. Another previously tested product was used at 50% dilution. A mix of two dibasic esters from DuPont was used in a 50-50 ratio. The client supplied product was used at full strength. Each solution was heated to 130 in a 40 kHz ultrasonic tank.
The contaminant consisted of a water based paint at 40 parts, a cross-linker (64265-57-2) at 2 parts and DI water at 1 part. The mixed paint was applied to fifteen preweighed steel coupons and allowed to dry. A second weight was recorded to determine the amount of paint applied.
Three painted coupons were immersed in a cleaning product and cleaned for 10 minutes using the 40 kHz ultrasonic tank. After the cleaning, coupons were rinsed in a tap water bath for 15 seconds at 120 F and air dried for 30 seconds at room temperature. The coupons were then rubbed with a gloved hand to determine how easily the paint could be removed. Once dry, the coupons were weighed a final time and removal efficiencies were calculated.
Trial Results:
Two of the alternatives worked very well after 10 minutes of cleaning. The Inproclean 4000 T was easily wiped from the surface after cleaning. The SC Actisolv allowed the paint to be removed during drying with air blow off. The table below lists the amount of paint applied, the amount remaining and the effectiveness of the products.
Cleaner | Initial wt | Final wt | % Removed | Observations |
Inproclean 4000 T | 0.0839 | 0.0030 | 96.42 | Rubbed off |
0.0779 | 0.0038 | 95.12 | ||
0.0502 | 0.0002 | 99.60 | ||
SC Acitsolv | 0.0347 | 0.0036 | 89.63 | Easily wiped off |
0.0850 | 0.0016 | 98.12 | ||
0.0603 | 0.0003 | 99.50 | ||
DBE 5/6 | 0.0527 | 0.1315 | -149.53 | No removal |
0.0542 | 0.1259 | -132.29 | ||
0.0671 | 0.1621 | -141.58 | ||
Surface Cleanse 930 | 0.0656 | 0.0319 | 51.37 | Some rub off |
0.0615 | 0.0635 | -3.25 | ||
0.0427 | 0.0124 | 70.96 | ||
D Zolve 1012 | 0.0394 | 0.0004 | 98.98 | |
0.0743 | 0.0004 | 99.46 | ||
0.0513 | 0.0021 | 95.91 |
Success Rating:
A follow up test, usually based on company input.Conclusion:
The two effective alternatives will be used to clean the reaming supplied spindles.