Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate products on second supplied cutting fluid
Date Run:
02/22/2008Experiment Procedure:
Four new product samples of solvents used for hand dipping applications at room temperature were chosen. Twelve preweighed coupons were coated with Master Chemical Corporation Trim Sol sf (8002-05-9, 61789-85-3, 68410-99-1, 68991-48-0, 68603-15-6) cutting fluid using a hand held swab. The contaminated coupons were weighed a second time to determine the amount of soil added. Three coupons were immersed into each cleaning solution and manual raised and lowered in the cleaning solution to provide minimal mechanical agitation. After one minute of cleaning, the coupons were removed and dried for 30 seconds using compressed air at room temperature. Following air drying, the coupons were weighed a final time to determine the amount of soil remaining. Efficiency for each coupon was determined and average cleaning results for each product were calculated.
Trial Results:
All four products removed over 99% of the cutting fluid within one minute. The table below lists the amount of soil added, the amount remaining and the affiance for each coupon cleaned.
Cleaner | Initial wt | Final wt | % Removed |
Dysol 104 | 0.1174 | 0.0000 | 100.00 |
0.0808 | 0.0002 | 99.75 | |
0.0932 | 0.0001 | 99.89 | |
Dysol 108 | 0.1227 | 0.0001 | 99.92 |
0.0632 | -0.0001 | 100.16 | |
0.1578 | 0.0001 | 99.94 | |
Dysol 144 | 0.0614 | 0.0002 | 99.67 |
0.1348 | 0.0002 | 99.85 | |
0.1096 | 0.0002 | 99.82 | |
Dysol 800 | 0.0159 | 0.0000 | 100.00 |
0.1068 | 0.0003 | 99.72 | |
0.1106 | 0.0002 | 99.82 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
All four products removed over 98% of the contaminant. The top products will be used on supplied parts and other client supplied soils.