Trial Purpose:
Evaluation of successful products using ultrasonics
Date Run:
08/08/2002Experiment Procedure:
Five products were selected from the previous trial based on their high efficiencies. The solutions were used at 68 F. The three semi-aqueous products were used at full strength and the two aqueous based products were diluted to 10% in 600 ml beakers using DI water.
Fifteen preweighed coupons were coated with Alpha Metals 615 Flux (67-63-0, 8052-41-3, 8050-09-7) using a handheld swab and allowed to dry. Coupons were then reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar agitation, then rinsed in tap water at 68 F for 15 seconds followed by an air knife drying for 30 seconds. Once dry, final weights were recorded and efficiencies were calculated.
Trial Results:
All five products were very effective using ultrasonics for two minutes. Table 1 lists the efficiencies for each coupon cleaned.
Table 1. Cleaning Efficiencies
Cleaner | Initial wt of cont. | Final wt of cont. | %Cont Removed |
Bio T Max | 0.0414 | -0.0003 | 100.72 |
0.1571 | -0.0003 | 100.19 | |
0.1283 | 0.0004 | 99.69 | |
DS 108 | 0.1235 | 0.0026 | 97.89 |
0.0982 | 0.0003 | 99.69 | |
0.1142 | -0.0005 | 100.44 | |
Ionox HC 2 | 0.1354 | -0.0001 | 100.07 |
0.1060 | -0.0003 | 100.28 | |
0.1274 | -0.0008 | 100.63 | |
SWR One | 0.0916 | -0.0002 | 100.22 |
0.1154 | -0.0009 | 100.78 | |
0.0942 | -0.0006 | 100.64 | |
Beyond 2005 | 0.0949 | 0.0061 | 93.57 |
0.1050 | 0.0002 | 99.81 | |
0.1306 | 0.0015 | 98.85 |
Success Rating:
A follow up test, usually based on company input.Conclusion:
These five products will be used on supplied parts from client.