Trial Purpose:
To evaluate the efficiency of various heated drop in solvent replacement in removing Momentive Grease from Brass.
Date Run:
03/25/2016Experiment Procedure:
Brass coupons were weighed to get their initial weights. The bottom third of each coupon was coated in the Momentive Grease. The coupons were re- weighed. The weights were recorded. The coupons were placed in the heated drop-in solvent replacement for 5 minutes. The coupons were removed out of the cleaning solution and placed to dry on a rack for 15 minutes. Then the final weights were taken and recorded.
Trial Results:
Cleaner | Initial wt of cont. | Final wt of cont. | %Cont Removed |
Ethyl 408 | 0.1908 | 0.2020 | -5.87 |
0.1552 | 0.1623 | -4.57 | |
0.1479 | 0.1566 | -5.88 | |
Methyl 408 | 0.1358 | 0.1368 | -0.74 |
0.1055 | 0.1066 | -1.04 | |
0.1244 | 0.1252 | -0.64 | |
FluoSolv CX | 0.1023 | 0.0287 | 71.95 |
0.0962 | 0.0258 | 73.18 | |
0.1043 | 0.0489 | 53.12 | |
FluoSolv NC | 0.1358 | 0.0610 | 55.08 |
0.1116 | 0.0382 | 65.77 | |
0.1006 | 0.0481 | 52.19 | |
Honeywell PF | 0.1800 | 0.0699 | 61.17 |
0.1248 | 0.0643 | 48.48 | |
0.1412 | 0.0723 | 48.8 | |
Honeywell PF 2A | 0.1350 | 0.0694 | 48.59 |
0.1475 | 0.0776 | 47.39 | |
0.1061 | 0.0617 | 41.85 | |
Vertrel Sion | 0.1859 | 0.0047 | 97.47 |
0.1792 | 0.0286 | 84.04 | |
0.3030 | 0.0709 | 76.6 | |
Fluosolv CX-500 | 0.8387 | 0.8123 | 3.15 |
0.7091 | 0.6861 | 3.24 | |
0.7496 | 0.7184 | 4.16 | |
Fluosolv FR-110 | 0.4448 | 0.4192 | 5.76 |
0.3955 | 0.3733 | 5.61 | |
0.3778 | 0.3513 | 7.01 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.