Default object view. Click to create a custom template, Node ID: 4373, Object ID: 4372

Project #2

Project #2

Replacement of Solvon PB to alkaline system.

Yes

No

No

07/12/2004

Carol Shibles
Andy Harris

Aerospace, medical electronics

various

Smooth

Hard

Complex

Yes

Yes

received from outside company

Plating

10000

20-500

Baron

Solvon PB

100

160

5-15

Use of solvent

Prepare parts for plating

No relation

No relation

Eight trials were conducted with student intern working at client. Cleaning results piloted in the lab with supplied parts. Five products appeared to remove all of the Rustilo. Only two parts with ball bearings had less than 95% removal with ultrasonics. Buckeye Aeromaster, Safety Kleen Corporation Armaklean M Aero NS, Brulin Corporation 815 QR, McGean Rohco Inc Alkalume LN and Today & Beyond 2004 were the successful products. Piloting has been implemented at the client's facility.

Yes

No

No

No

Yes

Name Class Section
Document Trial #0 Trial 3
Document Trial #1 Trial 3
Document Trial #2 Trial 3
Document Trial #3 Trial 3
Document Trial #4 Trial 3
Document Trial #5 Trial 3
Document Trial #6 Trial 3
Document Trial #7 Trial 3