Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate successful products on third supplied contaminant
Date Run:
05/05/2004Experiment Procedure:
Nine products were selected based on success in previous two trials. Each product was used at full strength in a 250 ml beaker and heated to 96 F on a hot plate. Twenty-seven preweighed silver plated copper coupons were coated with the Lanson Oil Co Vanish 6912 (6742-48-9) using a hand held swab. Coupons were weighed a second time to determine the amount of soil added to each coupon. Three coupons were cleaned in each solution for 5 minutes using stir-bar agitation. After cleaning parts were weighed a final time and efficiencies were calculated.
Trial Results:
Eight of the products removed over 80% of the soil within five minutes. Five of the nine products removed over 90%. The table lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.
Cleaner | Initial wt | Final wt | % Removed |
HFE 7100 | 0.0377 | 0.0013 | 96.55 |
0.0396 | 0.0021 | 94.70 | |
0.0496 | 0.0024 | 95.16 | |
HFE 7200 | 0.0962 | 0.0505 | 47.51 |
0.0378 | 0.0027 | 92.86 | |
0.0221 | 0.0007 | 96.83 | |
AK 225 | 0.0191 | 0.0046 | 75.92 |
0.0361 | 0.0065 | 81.99 | |
0.0484 | 0.0035 | 92.77 | |
Vertrel CCA | 0.0461 | 0.0020 | 95.66 |
0.0149 | 0.0014 | 90.60 | |
0.0689 | 0.0022 | 96.81 | |
Ensolv | 0.1084 | 0.0043 | 96.03 |
0.0444 | 0.0048 | 89.19 | |
0.0516 | 0.0043 | 91.67 | |
Ensolv A | 0.0143 | 0.0050 | 65.03 |
0.0450 | 0.0052 | 88.44 | |
0.0345 | 0.0046 | 86.67 | |
Metalnox M6760 | 0.0387 | 0.0045 | 88.37 |
0.0410 | 0.0036 | 91.22 | |
0.0146 | 0.0045 | 69.18 | |
Solvon PB | 0.0549 | 0.0011 | 98.00 |
0.0275 | 0.0024 | 91.27 | |
0.0220 | 0.0022 | 90.00 | |
Solvon IP | 0.0490 | 0.0023 | 95.31 |
0.0489 | 0.0029 | 94.07 | |
0.0431 | 0.0042 | 90.26 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
The products removing over 82% of the contaminant will be used on the fourth supplied soil.