Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
02/25/2002Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Cleaning: 5 min. immersion at 120 F with stir-bar agitation.
Rinsing: 1/2 min. manual with water at 120 F.
Drying: 1 min. with heat gun at 500 F.
Contaminant: Ink: ITW Dykem
CAS#: 64175, 123864, 71363, 9004700, 67630, 8004873.
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
None of the cleaners were effective.