Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 6

Trial Purpose:

To determine the efficacy of aqueous cleaners compared to water utilizing VCN equipment.

Date Run:

11/15/2023

Experiment Procedure:

Three pre weighed aluminum complex mesh parts were used as coupons. The coupons were soiled by swabbing the bottom third of the coupons with water coolant.  The dirty weights of the coupons were then recorded and visual rankings according to the key shown below were recorded.  The coupons were then subjected to a one-minute heated cycle at 140 degrees F in the VCN using Suma Break Up Heavy Duty Foaming Grease Release Cleaner 1% concentration.  The coupons were then removed and left to air dry overnight.  The next day the clean weights of the coupons were recorded, and visual rankings were recorded.  

Visual Rankings Key

1= 100% of soil removed

2= 75% of soil removed

3= 50% of soil removed

4= 25% of soil removed

5= 0% of soil removed

Trial Results:

Cleaner Soil Initial wt of cont. Final wt of cont. %Cont Removed % AVG
Suma Break Up 1% Water Coolant 0.6547 0.3347 48.88 37.91
0.7516 0.4357 42.03
0.7025 0.5421 22.83
Cleaner Soil Dirty Visual Clean Visual AVG Clean Visual
Suma Break Up 1% Water Coolant 5 2 2
5 2
5 2

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

The Suma Break Up 1% concentration was not effective in removing water coolant from complex aluminum mesh pieces utilizing VCN methods. 