Trial Purpose:
To evaluate aqueous alternatives using ultrasonic energy on second supplied contaminant.
Date Run:
08/07/2008Experiment Procedure:
Six products from previous trials were selected for testing. Five of the products were diluted to 20% and the sixth product was diluted to 5%. Products were heated to 130 F and immersed in a Branson 40 kHz ultrasonic tank and degassed for at least five minutes.
Eighteen preweighed coupons were coated with the supplied rust preventative using a handheld swab and weighed a second time to determine the amount of soil added. Three coupons were cleaned with ultrasonic energy for five minutes, rinsed in tap water for 15 seconds at 120 F and dried using compressed air at room temperature for 30 seconds. Final weights were recorded, and efficiencies calculated for each coupon cleaned.
Trial Results:
All six products removed more than 85% of the rust preventative, five of which removed more than 97%. The table lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.
Cleaner | Initial wt | Final wt | % Removed |
Shopmaster LpH | 0.2113 | 0.0024 | 98.86 |
0.1915 | 0.0065 | 96.61 | |
0.1883 | 0.0083 | 95.59 | |
Aquavantage 1400 GD | 0.2512 | 0.0046 | 98.17 |
0.2158 | 0.0040 | 98.15 | |
0.2592 | -0.0037 | 101.43 | |
Shopmaster HP | 0.2616 | 0.0286 | 89.07 |
0.2433 | 0.0361 | 85.16 | |
0.2283 | 0.0221 | 90.32 | |
Inproclean 3800 | 0.2791 | 0.0065 | 97.67 |
0.2603 | -0.0034 | 101.31 | |
0.2445 | 0.0022 | 99.10 | |
Bio T 300 B | 0.2305 | 0.0188 | 91.84 |
0.2645 | -0.0003 | 100.11 | |
0.2121 | 0.0044 | 97.93 | |
SC Aircraft & Metal Cleaner | 0.2868 | 0.0040 | 98.61 |
0.2760 | -0.0033 | 101.20 | |
0.2607 | -0.0005 | 100.19 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
All six will be evaluated next on the supplied grinding fluid.