Trial Number 1

Trial Purpose:

To evaluate the effectiveness of the AGAE Dishwasher Gel against Cascade Complete Dishwasher Gel and Seventh Generation Dishwasher Gel on the removal of Food Soil from ceramic plates and glassware by automatic dishwashing.

Date Run:

08/10/2018

Experiment Procedure:

All ceramic plates and glassware were previously cleaned and dried when 40 g of Soil DCC 05A Food (80% Margarine and 20% Non-Fat Powdered Milk) was evenly distributed onto six plates. The mechanical dishwasher was running previously to increase the temperature to 75° F, for the testing. The six soiled plates were placed on the lower rack uniformly, and six tall glass tumblers and four small glass tumblers were placed uniformly on the upper rack. The detergent slot was filled with the respective dishwasher gel and the test was then run for 42 minutes. After the cycle was completed the six tall glass tumblers and the four small glass tumblers were removed and inspected for spotting and filming by three examiners, and placed in their exact former locations. The six ceramic plates were re-soiled to the initial soil amount of 6.66 g and also placed in their former locations. The process was repeated five times for each dishwasher gel.

The following rating system was used:

Rating Spotting Filming
1 No Spots None
2 Spots and Random Barely
3 About ¼ of Surface Covered Slight
4 About ½ of Surface Covered Moderate
5 Virtually Completely Covered Heavy

Trial Results:

 

 AGAE Dishwasher Gel

Cycle 1 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 2.89 3.89
1 4.5 4 4 4 3.5 4
2 2 3 3.5 5 3 3
3 2 2.5 3 4.5 4 4
4 2 4 3 3.5 3 3
5 2.5 2 3 5 3.5 4
6 2 2.5 2.5 5 4 4 2.54 2.63
Small Glass 1 2 1.5 3 2 2 3
2 2 3 2.5 2 2 3
3 2.5 3.5 3 2 4 3
4 3 2 2.5 2.5 3 3

 

Cycle 2 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 3.58 3.53
1 4.5 4 3.5 4 3.5 3.5
2 3.5 4 4 4.5 3 3.5
3 4 3 4 4.5 5 4
4 3 3 3 2.5 4 3
5 5 4.5 4 2.5 3.5 4
6 2 3 2.5 2 3 3.5 3.50 3.50
Small Glass 1 2.5 3.5 2.5 4 4 3.5
2 3 4 3 4.5 3.5 3.5
3 5 4.5 4 3 3.5 3
4 2 4 4 2 4 3.5

 

Cycle 3 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 3.67 3.81
1 3 3.5 3.5 4 3.5 2.5
2 4 4 4 4 3.5 4
3 2 3.5 2.5 5 4 3.5
4 4 4 3.5 3 3.5 3
5 4.5 5 4 3.5 5 4.5
6 4 4 3 4.5 4 3.5 4.42 3.96
Small Glass 1 4 4.5 4 3 4 4
2 3 4 3.5 3 4.5 4
3 5 5 5 5 4.5 4
4 5 5 5 3 4.5 4

 

Cycle 4 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 3.97 3.25
1 3.5 4 4 3 3 2.5
2 5 4.5 4 4.5 3 3.5
3 3.5 3.5 3.5 3 2 3
4 4 4.5 3.5 3 3 3
5 4 3.5 4.5 3.5 4 4.5
6 4.5 3.5 4 4.5 2.5 3 4.13 3.17
Small Glass 1 5 4.5 4.5 3 4 4.5
2 2 4 4.5 2 3.5 3
3 5 4 3.5 3 3.5 3
4 4 4.5 4 3 3 2.5

 

Cycle 5 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 3.83 3.25
1 3.5 3 3 3 3.5 2.5
2 3 3.5 4 2.5 3.5 3.5
3 4 4 4 3 3.5 4
4 4 4 3.5 4 2.5 2.5
5 4 4 4 4.5 2.5 3
6 5 4.5 4 4 3.5 3 4.38 3.67
Small Glass 1 5 4.5 4 4.5 3 3
2 5 4 4 5 2.5 3
3 4.5 5 4.5 4 3.5 3.5
4 4.5 4 3.5 4 4 4

 

 Cascade Complete Dishwasher Gel

Cycle 1 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 2.36 1.94
1 2 2.5 2 2 1.5 2
2 3 2.5 2 2 2 2
3 2 3 3 1.5 2 2.5
4 2 2.5 2 2 1.5 2
5 2.5 2.5 3 2 2 2
6 3 1.5 1.5 2 1.5 2.5 2.33 2.29
Small Glass 1 2.5 2.5 2 1.5 1.5 2
2 3 2 1.5 3.5 3 2
3 3.5 3 2 3.5 3 2.5
4 2.5 2 1.5 2 1.5 1.5

 

Cycle 2 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 2.58 1.83
1 2 2 1.5 2 2 1.5
2 3 2.5 2 3 2 2
3 3.5 3 2 2 2 1.5
4 3 3 2.5 2 1.5 1.5
5 3.5 3.5 3 2 1.5 1.5
6 2.5 2 2 2 1.5 1.5 2.96 1.92
Small Glass 1 2 2 2.5 1.5 1.5 2
2 2.5 3 2.5 2 1.5 1.5
3 4.5 3.5 3 3 2 2
4 4 3.5 2.5 2 2 2

 

Cycle 3 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 2.42 2.03
1 2 2 2 2.5 2 1.5
2 2.5 2.5 2 2 2.5 2.5
3 2.5 2 1.5 2.5 1.5 1.5
4 3 2.5 2 3 2 1.5
5 3 3 2.5 2 2 2
6 3 2.5 3 1.5 1.5 2.5 3.54 2.42
Small Glass 1 4 3.5 3.5 3 2 2.5
2 4 2 2.5 3 2.5 2.5
3 4.5 4 4 2.5 2 2.5
4 4 3.5 3 2 2.5 2

 

Cycle 4 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 2.39 1.94
1 3 2 1.5 2 2 1.5
2 2 2 1.5 2 3 2
3 3.5 2.5 2 2 1.5 1.5
4 3 3.5 3 2 2 2
5 3 2.5 2.5 2 2.5 2
6 2 1.5 2 2 1.5 1.5 3.67 2.50
Small Glass 1 4 3.5 3 2 3 2.5
2 3.5 2 2.5 2.5 2 2
3 4 4 3.5 2.5 2.5 2.5
4 4.5 5 4.5 2.5 3 3

 

Cycle 5 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 2.67 1.97
1 3 2.5 1.5 2 2 1.5
2 3.5 1.5 2 2 2 2
3 2.5 2.5 2 2 2 1.5
4 3 3 2.5 2 1.5 2
5 4 3.5 3 2 2.5 2.5
6 3 3 2 2 2 2 3.50 2.63
Small Glass 1 3.5 4 3.5 2 2 2
2 4 2 2 2 2 1.5
3 3.5 3 3.5 2 2.5 2
4 5 4 4 2 3 2.5

 

Seventh Generation Dishwasher Gel

Cycle 1 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 2.83 2.31
1 3 2.5 2 1.5 2 2
2 3.5 3 2 2 2.5 3
3 4 3 2.5 3 3 2.5
4 3.5 2.5 2.5 2 2 2
5 3.5 2 2 2 2 3
6 4 3 2.5 2 2 3 3.21 1.92
Small Glass 1 2.5 3 2 2 1.5 2
2 4 4 2.5 2 2 2.5
3 4.5 3.5 3.5 1.5 2 2
4 3 3 3 2 1.5 2

 

Cycle 2 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 2.94 2.00
1 2.5 2.5 2.5 2 2 1.5
2 3 3.5 2.5 2 1.5 1.5
3 3 3 3 2 2 2
4 3.5 3.5 3 2 2.5 2
5 3 3 2.5 2 2.5 2.5
6 3.5 2.5 3 2 2 2 3.79 2.08
Small Glass 1 4 3 3 2.5 1.5 1.5
2 3 4 3.5 2 2 1.5
3 5 4 4 2.5 2 2.5
4 4 4 4 2 2.5 2.5

 

Cycle 3 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 3.28 2.42
1 2 3 2 2 2 2
2 4 3.5 3 2 3 2.5
3 4 3 3 2 2.5 2.5
4 3.5 3.5 3 2 2 2
5 4 3.5 3 2.5 3 2.5
6 4.5 3.5 3 3 3.5 2.5 3.88 2.13
Small Glass 1 3.5 4 3.5 2.5 2 2.5
2 4 4 3.5 2 1.5 1.5
3 4 4 4 3 2.5 2.5
4 4 4 4 2 2 1.5

 

Cycle 4 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 3.67 2.31
1 3 3.5 2.5 2 2 2
2 4 3 2.5 2 2 2
3 4.5 4 3.5 3 2.5 3
4 4 4 4 2 3 2.5
5 4 3.5 3.5 2 2 2.5
6 4.5 4 4 2.5 2 2.5 4.29 2.13
Small Glass 1 5 4 4 2 2 2
2 4.5 3.5 3.5 2 2 2.5
3 5 4.5 4.5 1.5 2.5 2.5
4 5 4 4 3 2 1.5

 

Cycle 5 Tall Glass Glass Number Spotting Rating Filming Rating Average Spotting Average Filming
Examiner 1 Examiner 2 Examiner 3 Examiner 1 Examiner 2 Examiner 3 3.36 2.17
1 3 3.5 2.5 2 2 2
2 3.5 2.5 2.5 2 2.5 2
3 4 3 2.5 2 2 2.5
4 4 3.5 3.5 2 2 2.5
5 3.5 4 3.5 1.5 2 3
6 4 4 3.5 2 2.5 2.5 4.25 2.36
Small Glass 1 3.5 4 4 2 2 2
2 3 4.5 4 2 2.5 2.5
3 4 5 4.5 2.5 2.5 2.5
4 4.5 5 5 2 3 3

 

Summary:

Tall Glass Spotting Averages

Dishwasher Gel Evaluated Cycle 1 Cycle 2 Cycle 3 Cycle 4 Cycle 5 Total Cycle Average
AGAE 2.89 3.58 3.67 3.97 3.83 3.59
Cascade Complete 2.36 2.58 2.42 2.39 2.67 2.48
Seventh Generation 2.83 2.94 3.28 3.67 3.36 3.22

 Tall Glass Filming Averages

Dishwasher Gel Evaluated Cycle 1 Cycle 2 Cycle 3 Cycle 4 Cycle 5 Total Cycle Average
AGAE 3.89 3.53 3.81 3.25 3.25 3.55
Cascade Complete 1.94 1.83 2.03 1.94 1.97 1.94
Seventh Generation 2.31 2.00 2.42 2.31 2.17 2.24

 Small Glass Spotting Averages

Dishwasher Gel Evaluated Cycle 1 Cycle 2 Cycle 3 Cycle 4 Cycle 5 Total Cycle Average
AGAE 2.54 3.50 4.42 4.13 4.38             3.79
Cascade Complete 2.33 2.96 3.54 3.67 3.50 3.20
Seventh Generation 3.21 3.79 3.88 4.29 4.25 3.88

 

Small Glass Filming Averages

Dishwasher Gel Evaluated Cycle 1 Cycle 2 Cycle 3 Cycle 4 Cycle 5 Total Cycle Average
AGAE 2.63 3.50 3.96 3.17 3.67             3.39
Cascade Complete 2.29 1.92 2.42 2.50 2.63 2.35
Seventh Generation 1.92 2.08 2.13 2.13 2.36 2.12

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

The Cascade Complete Dishwasher Gel was the most effective overall (tall and small glassware) compared to the Seventh Generation Dishwasher Gel, which in turn was more effective than the AGAE Dishwasher Gel.