Browse Client Types

Browse past lab clients by general industry sectors

Client #458

Project Number 1

Test Objective:

Identify an alternative to TCE

Product Use:

piano hinge and frame of emergency cabinets
Trial Number Date Run Purpose Success Rating
0 10/04/2019 To evaluate cleaners removing vanishing oil on company provided steel coupons. Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.
1 01/07/2020 To evaluate cleaners removing vanishing oil on TURI provided steel coupons. Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.
2 02/10/2020 To determine the effectiveness of three aqueous cleaners in heated ultrasonics 125F. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
3 02/19/2020 To determine if the aqueous cleaners are stripping the steel coupons provided by the company. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
4 02/24/2020 To determine the effectiveness of aqueous cleaners in removing Vanishing Oil from steel coupons provided by the company. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
5 03/02/2020 To determine the effectiveness of aqueous cleaners in removing Vanishing Oil provided by the company from TURI stainless steel coupons. Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.
6 08/20/2020 The purpose of this experiment was to determine the effectiveness of four selected cleaners in removing Vanishing Oil from TURI steel coupons using unheated immersion. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
7 09/01/2020 The purpose of this experiment was to determine the effectiveness of 4 selected cleaners in removing Vanishing Oil from TURI zinc plated steel coupons using heated immersion. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
8 09/10/2020 Evaluate aqueous and solvent cleaners to remove oil from steel. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
9 09/14/2020 The purpose of this experiment was to confirm removal results from Trial #8. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
10 09/14/2020 The purpose of this experiment was to determine the effectiveness of the new set of cleaners in removing Vanishing Oil from company provided cold rolled steel coupons. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
11 09/08/2020 The purpose of this experiment was to determine the effectiveness of 4 cleaners in removing Vanishing Oil from TURI general steel coupons using heated immersion and comparing the contact angle of cleaned coupons to that of solvent cleaned cold rolled steel coupons provided by the company. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
12 09/09/2020 The purpose of this experiment was to test the effectiveness of 4 cleaners in removing Vanishing Oil from cold rolled steel coupons provided by the company and comparing the contact angles to solvent cleaned coupons. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
13 09/16/2020 The purpose of this experiment was to determine the effectiveness of 4 cleaners on removing vanishing oil from company provided solvent cleaned cold rolled steel piano hinges. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
14 09/21/2020 The purpose of this experiment was to determine the effectiveness of the top two performing cleaners in removing vanishing oil from a company provided solvent cleaned galvanized steel piano hinge. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.