Browse Client Types

Browse past lab clients by general industry sectors

Client #456

Project Number 1

Test Objective:

Find a safer alternative to replace TCE

Product Use:

Used for gyroscopes
Trial Number Date Run Purpose Success Rating
0 06/16/2020 To evaluate the effectiveness and performance of various cleaners on the removal of rosin #4 from glass coupons. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
1 06/18/2020 To evaluate the effectiveness and performance of various cleaners on the removal of rosin #4 from glass coupons with a heated immersion process. Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.
2 07/10/2020 The purpose of this experiment is to determine the effectiveness of seven cleaners in removing rosin from glass substrates using heated immersion. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
3 07/16/2020 The purpose of this experiment was to determine the effectiveness of heated immersion with a stir bar for the removal of pitch and protect-o-coat contaminants. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
4 07/23/2020 The purpose of this experiment was to evaluate the effectiveness of cleaners to remove Rosin 2 (Pitch) and Protectocoat from glass substrates using heated ultrasonics. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
5 07/30/2020 The purpose of this experiment was to determine the effectiveness of high performing cleaners in removing the protect-o-coat soil from parts provided by the company with heated ultrasonics. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
6 10/05/2020 The purpose of this experiment was to perform a 60-minute heated immersion test on Mirachem 500 using Contaminant #4. Test requested by company. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
7 10/06/2020 The purpose of this experiment was to repeat 30 minute heated immersion with a stir bar using Mirachem 500 as requested by the company. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.