Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
12/05/2002Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Degassing: Degassing the solution by keeping solutions in ultrasonic crest for 5 min at 120 F.
Cleaning: Ultrasonic for 5 min. at 120 F.
Rinsing: 1/2 min. manual with water at 120 F.
Drying: 1 min with heat gun @ 500F
Contaminant: VOC Free No Clean Flux, CAS# 7732-18-5, 68937-72-4
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.